Hitachi Error Codes

Hitachi RAS / Utopia / Set Free shows numeric alarm codes on the PC-ARFP / PC-ARFG controller and outdoor 7-segment.

01

Indoor protection device tripped

Cause:
Drain float, freeze etc.
Action:
Read indoor sub-alarm; clear drain or airflow issue.

02

Outdoor protection device tripped

Cause:
HP switch or similar
Action:
Check HP switch, charge and condenser.

03

Indoor ↔ outdoor communication failure

Cause:
1-2 comms cable or PCB
Action:
Check 1-2 wiring polarity and PCBs.

04

Inverter ↔ control PCB comms failure

Cause:
Internal outdoor comms loss
Action:
Re-seat ribbon between PCBs; replace if needed.

05

Power source phase abnormal (3-ph)

Cause:
Phase loss / reverse
Action:
Swap two phases or repair supply.

06

Voltage drop on inverter

Cause:
Low DC bus / mains
Action:
Measure supply and DC bus.

07

Decrease in discharge gas superheat

Cause:
EEV overfeed / overcharge
Action:
Check EEV stepping and charge.

08

Increase in discharge gas temperature

Cause:
Low charge / EEV closed
Action:
Check charge, EEV, Td sensor.

0B

Outdoor air thermistor fault

Cause:
Open / short OAT sensor
Action:
Replace OAT thermistor.

0C

Outdoor coil thermistor fault

Cause:
Open / short coil sensor
Action:
Replace coil thermistor.

0D

Discharge gas thermistor fault

Cause:
Open / short Td sensor
Action:
Replace Td sensor.

11

Indoor return air sensor fault

Cause:
Open / short return sensor
Action:
Replace return air thermistor.

12

Indoor outlet air sensor fault

Cause:
Open / short outlet sensor
Action:
Replace outlet air thermistor.

13

Indoor freeze protection thermistor fault

Cause:
Open / short coil sensor
Action:
Replace freeze thermistor.

14

Indoor gas pipe thermistor fault

Cause:
Open / short gas pipe sensor
Action:
Replace gas pipe thermistor.

19

Indoor fan motor protection

Cause:
Stalled / overheated fan
Action:
Test motor; check airflow.

31

Indoor/outdoor capacity setting incorrect

Cause:
DIP setting mismatch
Action:
Set DIP per install manual.

38

Outdoor protection circuit abnormal

Cause:
PCB protection input fault
Action:
Check protection inputs / PCB.

EE

Compressor protection alarm

Cause:
Repeated compressor trips
Action:
Investigate prior alarms; service compressor circuit.

For field guidance only. Codes and procedures vary by model and firmware — always confirm with the Hitachi service manual for the specific unit before carrying out a repair.