Midea Error Codes

Midea (and rebadges incl. Comfee, some Bosch/Olimpia) shows E/P/F codes on the wired/wireless controller.

E0

Indoor unit EEPROM error

Cause:
Indoor PCB memory fault
Action:
Replace indoor PCB.

E1

Indoor ↔ outdoor communication error

Cause:
Comms wiring or PCB fault
Action:
Check S/N interconnect and replace PCB if needed.

E2

Zero-crossing detection error

Cause:
Mains zero-cross signal lost
Action:
Check supply and indoor PCB.

E3

Indoor fan speed out of control

Cause:
Stalled / failed fan motor
Action:
Test motor and capacitor (PSC) or driver (DC).

E4

Indoor room temperature sensor (T1) fault

Cause:
Open / short room sensor
Action:
Replace T1 thermistor.

E5

Indoor evaporator pipe sensor (T2) fault

Cause:
Open / short coil sensor
Action:
Replace T2 thermistor.

E6

Outdoor unit malfunction

Cause:
Outdoor side reports protection
Action:
Read outdoor LED code for sub-fault.

E7

Indoor EEPROM read error

Cause:
Indoor PCB EEPROM corrupt
Action:
Replace indoor PCB.

E8

Indoor / display panel communication error

Cause:
Display ribbon / connector fault
Action:
Re-seat ribbon, replace display PCB.

P0

Compressor IPM module protection

Cause:
Overcurrent, IPM failure
Action:
Megger compressor, replace inverter.

P1

Over / under voltage protection

Cause:
Mains supply out of range
Action:
Measure supply voltage.

P2

High temperature of IPM module

Cause:
IPM heatsink overheating
Action:
Clean heatsink, check thermal paste / fan.

P4

Inverter compressor drive error

Cause:
Inverter PCB fault
Action:
Replace inverter PCB.

P5

Outdoor fan speed out of control

Cause:
Stalled / failed outdoor fan
Action:
Test fan motor and driver.

P6

Low pressure protection

Cause:
Undercharge / blocked filter
Action:
Leak test and recharge.

F1

Outdoor ambient sensor (T4) fault

Cause:
Open / short OAT sensor
Action:
Replace OAT thermistor.

F2

Outdoor condenser sensor (T3) fault

Cause:
Open / short condenser sensor
Action:
Replace T3 thermistor.

F3

Discharge pipe sensor (T5) fault

Cause:
Open / short Td sensor
Action:
Replace T5 thermistor.

For field guidance only. Codes and procedures vary by model and firmware — always confirm with the Midea service manual for the specific unit before carrying out a repair.